engineering fundamentals DIVYA PROCESS INSTRUMENTS

DIVYA PROCESS INSTRUMENTS
Company
Profile

We are manufacturer & Exporter of Calibration Instruments for Temperature, Pressure & Vacuum. Started 1n 1996 we concentrate in the manufacture of calibration instruments and today many industries and calibration labs in India @ Abroad use our calibrators for the testing and calibration of Temperature Sensors, Temperature Switches, Pressure & Vacuum Gauges a Switches. All our calibrators are supplied along with calibration certificates that are traceable  to National Standards

Products

DRY TEMPERATURE CALIBRATOR

DEAD WEIGHT TESTER

DIGITAL PRESSURE CALIBRATOR

CALIBRATION TEST BENCH

TEMPERATURE SENSORS

Contact V.BALASUBRAMANIAN
Address 19/4, Mambalam High Road, T.Nagar, Chennai-17.
Country India
Telephone 0091-44-42047782
Fax 0091-44-42047782
Email dpi@airtelmail.in
Website www.divyaprocessinstruments.com
 Showcase Products
 

click image to enlarge.
DRY TEMPERATURE CALIBRATOR

Model  DPI-1100 is  a light weight, portable model suitable for the calibration & testing of sensors, thermometers and switches between 50.0 to 600.0 0C. Heated Block is made from AB alloy , Fuzzy Logic Controller for temperature control. Accuracy is 0.80C, stability is +/-0.20C.Supplied along with calibration certificate traceable to National & International standards.

Model DPI-1000 is also a light weight, portable model suitable for the calibration & testing of sensors, thermometers and switches between -30.0 to 90.0 0C. Cooled & Heated Block is made from Aluminium  , Peltier Cooler for cooling & Fuzzy Logic Controller for temperature control. Accuracy is 0.1 0C, stability is +/-0.05C and resolution is 0.01.Supplied along with calibration certificate traceable to National & International standards.


Model DPI-1200 is a Table Top Calibration Furnace  suitable for the calibration & testing of sensors, thermometers and switches between 100.0 to 1200 0C.  Heated Block is made from Ceramic Block , APM wires for heater & Fuzzy Logic Controller for temperature control. Accuracy is 3.0 0C, stability is +/-1.0 C and resolution is 1.0.Supplied along with calibration certificate traceable to National & International standards.

-Scientific Instruments > Test Equipment
-Test and Measurement > Calibration, Standards and Reference Sources
 

click image to enlarge.
DEAD WEIGHT TESTER

Model DPI-2100 Dead Weight Tester is suitable for the testing and calibration of Pressure Gauges and Pressure Switches. Available is single or dual piston models and available in different ranges. The accuracy is 0.1% for basic models and high accurate models having an accuracy of 0.05% is also available. Supplied along with calibration certificate traceable to National & International standards.

-Test and Measurement > Calibration, Standards and Reference Sources
 

click image to enlarge.
DIGITAL PRESSURE CALIBRATOR

THIS  CALIBRATOR APPLIES THE PASCAL'S LAW IN ITS USE. PRESSURE IS APPLIED ON THE LIQUID INSIDE THE CYLINDER OF THE SCREW PUMP BY THE MOVEMENT OF THE PISTON. PRESSURE GETS TRANSMITTED TO BOTH LIMBS EQUALLY AND IF A MASTER GAUGE IS CONNECTED ON ONE LIMB AND A TEST GAUGE ON THE OTHER LIMB, THEN BOTH SHOULD SHOW THE GENERATED PRESSURE EQUALLY. IF NOT, THE TEST GAUGE IS ADJUSTED. ACCURACY OF THE DIGITAL GAUGE IS 0.05% AND RANGE AVAILABLE IS 0 TO 700 BAR.

-Test and Measurement > Calibration, Standards and Reference Sources
 

click image to enlarge.
CALIBRATION TEST BENCH
DPI - 5000 Series Calibration & Test Bench is an ideal calibration and test set up which will meet the calibration requirement of any industry in total. The design is modular and the Calibration & Test Bench can be installed with few necessary modules initially and additional requirement can be added as & when the requirement arises. The Dimensions of the test bench varies depending upon the configuration. A full Calibration & Test Bench will include the following.

1.      Variable A/C Power Supply
         Provides a variable 8 A rated A.C output Voltage (Higher Ampere rating model is also available)

2.      Variable DC Power Supply
         Provides a variable (0 to 120VDC) 5 A rated D.C output voltage (Higher Ampere rating model is also available)

3.      61/2 Digits Multimeter (Agilent make)

4.      Dry Block Tmeperature Calibrator
        (Model DPI-1100 & Range 50 ~650.0°C)

5.      Low Temperature Dry Block Calibrator
        (Model DPI-1000 & Range -40.0~100.0°C)

6.      Dead Weight Tester or Digital Pressure Calibrator
         a) Dead Weight Tester Model DPI-2100 & Range 0 to 700.0 Kg/Cm2
         b) Digital Pressure Calibrator Model DPI-2000 & Range 0 to 500.0 Bar

7.      Vacuum Calibrator (Model DPI-900 & Range-700 to O.OmmHg)

8.      Universal Calibrator (Model DPI - 500)

-Test and Measurement > Calibration, Standards and Reference Sources
 
 

Related Product Categories
Scientific Instruments
Test Equipment
Instruments used to test, analyze, control, calibrate, display and record data in laboratory and other testing situations.
Test and Measurement
Calibration, Standards and Reference Sources
Calibration instruments, standards and references consist of an accurate meter or provide a precision source value.
Home  About Us  Privacy  Disclaimer  Contact  Advertise