engineering fundamentals
Wide Flange Steel I Beam: W21 × 101
Home | Directory | Career | News | Industrial




Materials

Design

Processes

Units

Formulas

Math
Glossary » Beams » Simply Supported » Uniformly Distributed Load » Single Span » Wide Flange Steel I Beam » W21 × 101
Wide Flange Steel I Beam | Single Span | Two Equal Spans | Three Equal Spans | Four Equal Spans

For a simply supported beam in a single span, the maximum displacement w_max and the maximum normal stress stress_max occur at the center of the beam.
The tabulated data listed in this page are calculated based on the area moment of inertia (Ixx = 2420 in4) for the W21 × 101 Wide Flange Steel I Beam and the typical Young's modulus (E = 3.046 × 107 psi) of steels. Note that the typical yielding stress Yield of steels can range from 1.015 × 104 to 2.970 × 105 psi. The purpose of this page is to give a rough estimation of the load-bearing capacity of this particular beam, rather than a guideline for designing actual building structures. Please check your local building codes for regulatory requirements.

Note: The weight of the beam itself is not included in the calculation.
L = 3 ft
L = 5 ft
L = 10 ft
L = 15 ft
L = 20 ft
L = 25 ft
L = 30 ft
L = 40 ft
L = 50 ft
L = 60 ft
L = 70 ft
L = 80 ft
L = 90 ft
L = 100 ft
L = 125 ft
L = 150 ft
  
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 3.00 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 2.50 × 10-6 6.02
200 4.95 × 10-6 11.9
300 7.42 × 10-6 17.9
400 9.89 × 10-6 23.8
500 1.24 × 10-5 29.8
600 1.48 × 10-5 35.7
700 1.73 × 10-5 41.7
800 1.98 × 10-5 47.7
900 2.23 × 10-5 53.6
1000 2.47 × 10-5 59.6
2000 4.95 × 10-5 119
3000 7.42 × 10-5 179
4000 9.89 × 10-5 238
5000 1.24 × 10-4 298
6000 1.48 × 10-4 357
7000 1.73 × 10-4 417
8000 1.98 × 10-4 477
9000 2.23 × 10-4 536
1.00 × 104 2.47 × 10-4 596
2.00 × 104 4.95 × 10-4 1190
3.00 × 104 7.42 × 10-4 1790
4.00 × 104 9.89 × 10-4 2380
5.00 × 104 0.00124 2980
6.00 × 104 0.00148 3570
7.00 × 104 0.00173 4170
8.00 × 104 0.00198 4770
9.00 × 104 0.00223 5360
1.00 × 105 0.00247 5960
2.00 × 105 0.00495 1.19 × 104
3.00 × 105 0.00742 1.79 × 104
4.00 × 105 0.00989 2.38 × 104
5.00 × 105 0.0124 2.98 × 104
6.00 × 105 0.0148 3.57 × 104
7.00 × 105 0.0173 4.17 × 104
8.00 × 105 0.0198 4.77 × 104
9.00 × 105 0.0223 5.36 × 104
1.00 × 106 0.0247 5.96 × 104
2.00 × 106 0.0495 1.19 × 105
3.00 × 106 0.0742 1.79 × 105
4.00 × 106 0.0989 2.38 × 105
4.99 × 106 0.123 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 5.00 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 1.93 × 10-5 16.7
200 3.82 × 10-5 33.1
300 5.72 × 10-5 49.6
400 7.63 × 10-5 66.2
500 9.54 × 10-5 82.7
600 1.14 × 10-4 99.3
700 1.34 × 10-4 116
800 1.53 × 10-4 132
900 1.72 × 10-4 149
1000 1.91 × 10-4 165
2000 3.82 × 10-4 331
3000 5.72 × 10-4 496
4000 7.63 × 10-4 662
5000 9.54 × 10-4 827
6000 0.00114 993
7000 0.00134 1160
8000 0.00153 1320
9000 0.00172 1490
1.00 × 104 0.00191 1650
2.00 × 104 0.00382 3310
3.00 × 104 0.00572 4960
4.00 × 104 0.00763 6620
5.00 × 104 0.00954 8270
6.00 × 104 0.0114 9930
7.00 × 104 0.0134 1.16 × 104
8.00 × 104 0.0153 1.32 × 104
9.00 × 104 0.0172 1.49 × 104
1.00 × 105 0.0191 1.65 × 104
2.00 × 105 0.0382 3.31 × 104
3.00 × 105 0.0572 4.96 × 104
4.00 × 105 0.0763 6.62 × 104
5.00 × 105 0.0954 8.27 × 104
6.00 × 105 0.114 9.93 × 104
7.00 × 105 0.134 1.16 × 105
8.00 × 105 0.153 1.32 × 105
9.00 × 105 0.172 1.49 × 105
1.00 × 106 0.191 1.65 × 105
1.79 × 106 0.342 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 10.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 3.08 × 10-4 66.9
200 6.11 × 10-4 132
300 9.16 × 10-4 199
400 0.00122 265
500 0.00153 331
600 0.00183 397
700 0.00214 463
800 0.00244 530
900 0.00275 596
1000 0.00305 662
2000 0.00611 1320
3000 0.00916 1990
4000 0.0122 2650
5000 0.0153 3310
6000 0.0183 3970
7000 0.0214 4630
8000 0.0244 5300
9000 0.0275 5960
1.00 × 104 0.0305 6620
2.00 × 104 0.0611 1.32 × 104
3.00 × 104 0.0916 1.99 × 104
4.00 × 104 0.122 2.65 × 104
5.00 × 104 0.153 3.31 × 104
6.00 × 104 0.183 3.97 × 104
7.00 × 104 0.214 4.63 × 104
8.00 × 104 0.244 5.30 × 104
9.00 × 104 0.275 5.96 × 104
1.00 × 105 0.305 6.62 × 104
2.00 × 105 0.611 1.32 × 105
3.00 × 105 0.916 1.99 × 105
4.00 × 105 1.22 2.65 × 105
4.49 × 105 1.37 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 15.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.00156 150
200 0.00309 298
300 0.00464 447
400 0.00618 596
500 0.00773 745
600 0.00927 894
700 0.0108 1040
800 0.0124 1190
900 0.0139 1340
1000 0.0155 1490
2000 0.0309 2980
3000 0.0464 4470
4000 0.0618 5960
5000 0.0773 7450
6000 0.0927 8940
7000 0.108 1.04 × 104
8000 0.124 1.19 × 104
9000 0.139 1.34 × 104
1.00 × 104 0.155 1.49 × 104
2.00 × 104 0.309 2.98 × 104
3.00 × 104 0.464 4.47 × 104
4.00 × 104 0.618 5.96 × 104
5.00 × 104 0.773 7.45 × 104
6.00 × 104 0.927 8.94 × 104
7.00 × 104 1.08 1.04 × 105
8.00 × 104 1.24 1.19 × 105
9.00 × 104 1.39 1.34 × 105
1.00 × 105 1.55 1.49 × 105
1.99 × 105 3.08 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 20.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.00493 267
200 0.00977 530
300 0.0147 794
400 0.0195 1060
500 0.0244 1320
600 0.0293 1590
700 0.0342 1850
800 0.0391 2120
900 0.0440 2380
1000 0.0488 2650
2000 0.0977 5300
3000 0.147 7940
4000 0.195 1.06 × 104
5000 0.244 1.32 × 104
6000 0.293 1.59 × 104
7000 0.342 1.85 × 104
8000 0.391 2.12 × 104
9000 0.440 2.38 × 104
1.00 × 104 0.488 2.65 × 104
2.00 × 104 0.977 5.30 × 104
3.00 × 104 1.47 7.94 × 104
4.00 × 104 1.95 1.06 × 105
5.00 × 104 2.44 1.32 × 105
6.00 × 104 2.93 1.59 × 105
7.00 × 104 3.42 1.85 × 105
8.00 × 104 3.91 2.12 × 105
9.00 × 104 4.40 2.38 × 105
1.00 × 105 4.88 2.65 × 105
1.12 × 105 5.48 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 25.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.0120 418
200 0.0238 827
300 0.0358 1240
400 0.0477 1650
500 0.0596 2070
600 0.0715 2480
700 0.0835 2900
800 0.0954 3310
900 0.107 3720
1000 0.119 4140
2000 0.238 8270
3000 0.358 1.24 × 104
4000 0.477 1.65 × 104
5000 0.596 2.07 × 104
6000 0.715 2.48 × 104
7000 0.835 2.90 × 104
8000 0.954 3.31 × 104
9000 1.07 3.72 × 104
1.00 × 104 1.19 4.14 × 104
2.00 × 104 2.38 8.27 × 104
3.00 × 104 3.58 1.24 × 105
4.00 × 104 4.77 1.65 × 105
5.00 × 104 5.96 2.07 × 105
6.00 × 104 7.15 2.48 × 105
7.00 × 104 8.35 2.90 × 105
7.18 × 104 8.56 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 30.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.0250 602
200 0.0495 1190
300 0.0742 1790
400 0.0989 2380
500 0.124 2980
600 0.148 3570
700 0.173 4170
800 0.198 4770
900 0.223 5360
1000 0.247 5960
2000 0.495 1.19 × 104
3000 0.742 1.79 × 104
4000 0.989 2.38 × 104
5000 1.24 2.98 × 104
6000 1.48 3.57 × 104
7000 1.73 4.17 × 104
8000 1.98 4.77 × 104
9000 2.23 5.36 × 104
1.00 × 104 2.47 5.96 × 104
2.00 × 104 4.95 1.19 × 105
3.00 × 104 7.42 1.79 × 105
4.00 × 104 9.89 2.38 × 105
4.99 × 104 12.3 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 40.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.0789 1070
200 0.156 2120
300 0.234 3180
400 0.313 4240
500 0.391 5300
600 0.469 6360
700 0.547 7410
800 0.625 8470
900 0.703 9530
1000 0.781 1.06 × 104
2000 1.56 2.12 × 104
3000 2.34 3.18 × 104
4000 3.13 4.24 × 104
5000 3.91 5.30 × 104
6000 4.69 6.36 × 104
7000 5.47 7.41 × 104
8000 6.25 8.47 × 104
9000 7.03 9.53 × 104
1.00 × 104 7.81 1.06 × 105
2.00 × 104 15.6 2.12 × 105
2.80 × 104 21.9 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 50.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.193 1670
200 0.382 3310
300 0.572 4960
400 0.763 6620
500 0.954 8270
600 1.14 9930
700 1.34 1.16 × 104
800 1.53 1.32 × 104
900 1.72 1.49 × 104
1000 1.91 1.65 × 104
2000 3.82 3.31 × 104
3000 5.72 4.96 × 104
4000 7.63 6.62 × 104
5000 9.54 8.27 × 104
6000 11.4 9.93 × 104
7000 13.4 1.16 × 105
8000 15.3 1.32 × 105
9000 17.2 1.49 × 105
1.00 × 104 19.1 1.65 × 105
1.79 × 104 34.2 2.97 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 60.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.400 2410
200 0.791 4770
300 1.19 7150
400 1.58 9530
500 1.98 1.19 × 104
600 2.37 1.43 × 104
700 2.77 1.67 × 104
800 3.16 1.91 × 104
900 3.56 2.14 × 104
1000 3.96 2.38 × 104
2000 7.91 4.77 × 104
3000 11.9 7.15 × 104
4000 15.8 9.53 × 104
5000 19.8 1.19 × 105
5400 21.4 1.29 × 105
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 70.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 0.740 3280
200 1.47 6490
300 2.20 9730
400 2.93 1.30 × 104
500 3.66 1.62 × 104
600 4.40 1.95 × 104
700 5.13 2.27 × 104
800 5.86 2.59 × 104
900 6.60 2.92 × 104
1000 7.33 3.24 × 104
2000 14.7 6.49 × 104
2910 21.4 9.45 × 104
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 80.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 1.26 4280
200 2.50 8470
300 3.75 1.27 × 104
400 5.00 1.69 × 104
500 6.25 2.12 × 104
600 7.50 2.54 × 104
700 8.75 2.97 × 104
800 10.0 3.39 × 104
900 11.3 3.81 × 104
1000 12.5 4.24 × 104
1710 21.4 7.24 × 104
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 90.0 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 2.02 5420
200 4.01 1.07 × 104
300 6.01 1.61 × 104
400 8.01 2.14 × 104
500 10.0 2.68 × 104
600 12.0 3.22 × 104
700 14.0 3.75 × 104
800 16.0 4.29 × 104
900 18.0 4.83 × 104
1000 20.0 5.36 × 104
1070 21.4 5.72 × 104
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 100 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 3.08 6690
200 6.11 1.32 × 104
300 9.16 1.99 × 104
400 12.2 2.65 × 104
500 15.3 3.31 × 104
600 18.3 3.97 × 104
700 21.4 4.63 × 104
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 125 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 7.53 1.04 × 104
200 14.9 2.07 × 104
287 21.4 2.96 × 104
Steel I Beam: W21 × 101 (Wide Flange 21 inch tall × 101 lbf/ft)
L = 150 ft
P (lbf/ft) w_max (in) stress_max (psi)
101 15.6 1.50 × 104
138 21.4 2.06 × 104
Additional Information
Home  About Us  Privacy  Disclaimer  Contact 

Copyright © 2018 eFunda, Inc.