Conditions | Tensile Properties |
T (°C) | Treatment |
25 |
(flat products, rod, wire, tube, pipe, shapes) |
Tensile Strength (MPa) |
221-455
|
Yield Strength (MPa) |
69-365
|
Elongation (%) |
55 |
Reduction in Area (%) |
|
Note: Elongation is measured in 4 inches. |
25 |
H55 (copper alloy tube OD=25 mm, thickness=1.65 mm) |
Tensile Strength (MPa) |
275 |
Yield Strength (MPa) |
220 |
Elongation (%) |
25 |
Reduction in Area (%) |
|
25 |
H80 (copper alloy tube OD=25 mm, thickness=1.65 mm) |
Tensile Strength (MPa) |
380 |
Yield Strength (MPa) |
345 |
Elongation (%) |
8 |
Reduction in Area (%) |
|
25 |
OS025 (copper alloy tube OD=25 mm, thickness=1.65 mm) |
Tensile Strength (MPa) |
235 |
Yield Strength (MPa) |
76 |
Elongation (%) |
45 |
Reduction in Area (%) |
|
25 |
OS050 (copper alloy tube OD=25 mm, thickness=1.65 mm) |
Tensile Strength (MPa) |
220 |
Yield Strength (MPa) |
69 |
Elongation (%) |
45 |
Reduction in Area (%) |
|